Notifications
You must be signed in to change notification settings - Fork 47
1.3 The temperature probe
matsstaff edited this page May 6, 2015
·
1 revision
The temperature probe that the STC-1000 uses is a 10k NTC thermistor with a β25°C/85°C value of 3435, presumably 1%.
It is connected to an analogue input on the MCU via a voltage divider as shown above.
Temperature [°C] | Resistance [Ohm] |
---|---|
-40.0 | 190953 |
-35.0 | 145953 |
-30.0 | 112440 |
-25.0 | 87285 |
-20.0 | 68260 |
-15.0 | 53762 |
-10.0 | 42636 |
-5.0 | 34038 |
0.0 | 27348 |
5.0 | 22108 |
10.0 | 17979 |
15.0 | 14706 |
20.0 | 12094 |
25.0 | 10000 |
30.0 | 8310.8 |
35.0 | 6941.1 |
40.0 | 5824.9 |
45.0 | 4910.6 |
50.0 | 4158.3 |
55.0 | 3536.2 |
60.0 | 3019.7 |
65.0 | 2588.8 |
70.0 | 2228.0 |
75.0 | 1924.6 |
80.0 | 1668.4 |
85.0 | 1451.3 |
90.0 | 1266.7 |
95.0 | 1109.2 |
100.0 | 974.26 |
105.0 | 858.33 |