Notifications
You must be signed in to change notification settings - Fork 3
Configure
first of all enable vbar on your window manager, example on i3wm
edit ~/.config/i3/config
bar{
status_command vbar
}
vbar need a configuration file for run
we have some config themes, you can view name with
$ ls themes
for install theme you can use script, for example i3 theme
$ ./theme.install i3
the base of config is in
~/.config/vbar/config
you can cange this directory and run vbar with -c
bar{
status_command vbar -c /your/vbar/config
}
each module have directory called with same name of module, example default dir for cpu module
~/.config/vbar/cpu/config
you can change this directory in base config file
setting variable:
property = value
property = value.value
property = "value"
property = 'value'
no multiline settings ar supported on quoted value.
Comment
# this is comment
text.long, text.short and event support interpretate command
interpreter start with dollar sign.
numeric value specific enviroment module
$0
$1
$2
$n
at sign specific the current icon value
$@
interpreter can execute some action
${action(var,var,...)}
set value for specific module
${set(instance,name,attribute,value)}
example hide cpu module on event
event = "${set(cpu,generic,hide,1)}"
Invert value, not all attribute support this action
${toggle(instance,name,attribute)}
example nvert hide cpu module on event
event = "${toggle(cpu,generic,hide)}"
the event attribute execute action or spawn command
execute urxvt when module event as triggered
event = "urxvt"
after lanch vbar search base config file, this file contains modules you want to load and the common configurations.
Before select module to load you can specific the common attribute for module, not all window manager support all value but not generate error.
Every attribute can be replaced on module/config file, each module export extra attribute.
# Module have two name, Instance isn't configurable, Name is configurable by user
# can load multiple module with differnt name
name = modulename
# time in ms to refresh module
# time -1 refresh only at boot
refresh = 1000
# enable blink urgent mode
blink = 1
# enable blink background color
blink = 2
# enable blink foreground color
# set blink color
blink.color = 0xFF0000
#text color
# -1 disable
color = 0xFF
# background color
# -1 disable
background = 0x0
# border color
# -1 disable
border = 0xFFFFFF
# minimal width
# -1 disable
min_width = 300
# align of text
align = center
# line separator
separator = 1
# distance for block
separator\_block\_width = 1
# enable markup
markup = 0
# hide module, hidden module is not refresh and not eventable
hide = 0
# text to be display
text.long = ""
# short text to be display
text.short = ''
# force to use text.short
text.short.enable = 0
# event for triggered module
event = ''
after setting common attribute can load module
if module not as in default directory change property before load
module.path = ~/.config/vbar/cpu/config
now you can load module
module.load = cpu
see wiki page module for configure module