Skip to content

Software stack for a bidirectional electric vehicle DC "fast" charging station based on EcoG/iso15118 + EVAcharge SE + EA-PSB

License

Notifications You must be signed in to change notification settings

securityinmobility/dc-charging-station

Repository files navigation

dc-charging-station

This repository contains glue code in order to create a fully working DC charging station.

In our case we use open-plc-utils for SLAC, EcoG-io/iso15118 for the ISO15118 stack, an EVAcharge SE for powerline communication and a Kratzer Automation battery tester EA-PSB 11000-10 as a bidirectional HV power supply.

Components

The idea of this repository is to have hardware abstraction interfaces which can be implemented for different hardware. All of these interfaces (python abstract base classes) are defined in the base_classes.py file.

For implementing a charging station you need to implement the ChargingStation class as well as the HighVoltageSource class. You can then give them as parameters to the ISO15118 EVSE controller based on EcoG-io/iso15118. This controller will handle vehicle detection, iso15118 communication and high voltage source parameter setting.

The SLAC process is implemented using EcoG-io/pyslac.

Running

For our current main test setup we use an EVAcharge SE, configured in network bridging mode and a EA-PSB 11000-10 configured for remote control via SCPI.

First connect to the evacharge via ssh, flash the modem and run socat for forwarding the low level controls.

# ./flash-qca-temporarily.sh
# socat tcp-l:2020,reuseaddr,fork,crlf file:/dev/ttyAPP2,echo=0,b57600,raw

In a second terminal start the actual charging station code:

$ python -m venv venv
$ . venv/bin/activate
$ pip install -r requirements.txt
$ NETWORK_INTERFACE=enx7cc2c61f051e FREE_CHARGING_SERVICE=True LOG_LEVEL=INFO python3 secc-main.py

After plugging in the vehicle the charging process should start automatically.

Environment Variables

dc-charging-station

These variables control the main application logic and the selection of hardware interface implementations.

ENV Default Value Description
LOG_LEVEL INFO The logging level for the Python log service. Applies to the entire application.
NETWORK_INTERFACE eth0 The network interface name (e.g., enx7cc2c61f051e) used for the communication.
HIGH_VOLTAGE_CONTROLLER_IMPL mock Specifies which implementation of the HighVoltageSource abstract base class to use.
DIN_61851_IMPL mock Specifies which implementation to use for the basic PWM signaling according to IEC 61851-1.
FREE_CHARGING_SERVICE False If set to True, the charging service is provided without requiring authorization.

pyslac (SLAC Protocol)

These variables are used to configure the SLAC (Signal Level Attenuation Characterization) process, which is managed by a pyslac adaptation.

ENV Default Value Description
SLAC_INIT_TIMEOUT 50 Timeout in seconds for the reception of the first SLAC message after Control Pilot state B is detected.
ATTEN_RESULTS_TIMEOUT None Timeout in milliseconds for the reception of all MNBC (Mid-Network Beaconing and Communication) sounds. If not set, the system uses the timeout defined by the EV.
EVSE_ID DE*THI*H007000000 The unique identifier of the charging point.
NID None The 56-bit Network Identifier (NID) for the SLAC protocol, used to identify the logical network.
NMK None The 128-bit Network Membership Key (NMK) for the SLAC protocol, used to secure the communication on the logical network.

SECC (ISO 15118 Communication)

These variables configure the SECC (Supply Equipment Communication Controller) and the high-level communication based on the ISO 15118 standard.

ENV Default Value Description
SECC_ENFORCE_TLS False If set to True, the SECC will enforce a TLS-secured connection for all communication.
PKI_PATH <CWD>/iso15118/shared/pki/ Path to the Public Key Infrastructure (PKI) directory containing the necessary certificates.
MESSAGE_LOG_JSON True Set to True to log the EXI messages as JSON. This requires the LOG_LEVEL to be set to DEBUG.
MESSAGE_LOG_EXI False Set to True to log the raw EXI bytestream messages. This requires the LOG_LEVEL to be set to DEBUG.
PROTOCOLS DIN_SPEC_70121,ISO_15118_2,... A comma-separated list of enabled communication protocols on the SECC.
AUTH_MODES EIM,PNC A comma-separated list of selected authentication modes for the SECC (e.g., EIM for External Identification Means, PNC for Plug and Charge).
USE_CPO_BACKEND False Set to True to indicate that a CPO (Charge Point Operator) backend is available to fetch certificates or authorization data.
ENABLE_TLS_1_3 False Set to True to enable the use of TLS version 1.3 for the communication link between the SECC and the EVCC.

Unit Tests

This repository is using pytest to test the implementations of interfaces to various devices. In the root directory use the following to run all tests:

pytest .