Skip to content

Commit

Permalink
Merge pull request JeffersonLab#51 from maureeungaro/main
Browse files Browse the repository at this point in the history
removed vacuumLine and added cad_downstream_beamline
  • Loading branch information
maureeungaro authored Oct 8, 2024
2 parents 13548c4 + 8f39206 commit 595f8f0
Show file tree
Hide file tree
Showing 20 changed files with 80 additions and 80 deletions.
8 changes: 4 additions & 4 deletions gemc/dev/clas12-default.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -30,10 +30,11 @@
<!-- Beamline configuration: FTOn is used -->
<detector name="experiments/clas12/ft/ft" factory="TEXT" variation="FTOn"/>
<detector name="experiments/clas12/beamline/cadBeamline/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="FTOn"/>


<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>

<!-- forward carriage -->
<detector name="experiments/clas12/fc/forwardCarriage" factory="TEXT" variation="default"/>
Expand Down Expand Up @@ -103,10 +104,9 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, 20" />


<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectUpstreamToTorusPipe, connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />

<!-- torus magnet: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="BoreShield, CenterTube, DownstreamShieldingPlate, DownstreamVacuumJacket, WarmBoreTube, apex, Shield1, Shield2, Shield3, Shield4, Shield5, Shield6, Shield7, shell1a, shell1b, shell2a, shell2b, shell3a, shell3b, shell4a, shell4b, shell5a, shell5b, shell6a, shell6b, 20" />
Expand Down
8 changes: 4 additions & 4 deletions gemc/dev/rga_fall2018.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -30,9 +30,10 @@
<!-- Beamline configuration: FTOn is used -->
<detector name="experiments/clas12/ft/ft" factory="TEXT" variation="FTOn"/>
<detector name="experiments/clas12/beamline/cadBeamline/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="FTOn"/>

<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>


<!-- forward carriage -->
Expand Down Expand Up @@ -103,10 +104,9 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, 20" />


<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectUpstreamToTorusPipe, connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />

<!-- torus magnet: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="BoreShield, CenterTube, DownstreamShieldingPlate, DownstreamVacuumJacket, WarmBoreTube, apex, Shield1, Shield2, Shield3, Shield4, Shield5, Shield6, Shield7, shell1a, shell1b, shell2a, shell2b, shell3a, shell3b, shell4a, shell4b, shell5a, shell5b, shell6a, shell6b, 20" />
Expand Down
8 changes: 4 additions & 4 deletions gemc/dev/rga_fall2018_target_at_m3.5.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -30,9 +30,10 @@
<!-- Beamline configuration: FTOn is used -->
<detector name="experiments/clas12/ft/ft" factory="TEXT" variation="FTOn"/>
<detector name="experiments/clas12/beamline/cadBeamline/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="FTOn"/>

<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>


<!-- forward carriage -->
Expand Down Expand Up @@ -103,10 +104,9 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, 20" />


<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectUpstreamToTorusPipe, connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />

<!-- torus magnet: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="BoreShield, CenterTube, DownstreamShieldingPlate, DownstreamVacuumJacket, WarmBoreTube, apex, Shield1, Shield2, Shield3, Shield4, Shield5, Shield6, Shield7, shell1a, shell1b, shell2a, shell2b, shell3a, shell3b, shell4a, shell4b, shell5a, shell5b, shell6a, shell6b, 20" />
Expand Down
8 changes: 4 additions & 4 deletions gemc/dev/rga_spring2018.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -30,9 +30,10 @@
<!-- Beamline configuration: FTOn is used -->
<detector name="experiments/clas12/ft/ft" factory="TEXT" variation="FTOn"/>
<detector name="experiments/clas12/beamline/cadBeamline/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="FTOn"/>

<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>


<!-- forward carriage -->
Expand Down Expand Up @@ -103,10 +104,9 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, 20" />


<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectUpstreamToTorusPipe, connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />

<!-- torus magnet: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="BoreShield, CenterTube, DownstreamShieldingPlate, DownstreamVacuumJacket, WarmBoreTube, apex, Shield1, Shield2, Shield3, Shield4, Shield5, Shield6, Shield7, shell1a, shell1b, shell2a, shell2b, shell3a, shell3b, shell4a, shell4b, shell5a, shell5b, shell6a, shell6b, 20" />
Expand Down
8 changes: 4 additions & 4 deletions gemc/dev/rga_spring2019.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -30,9 +30,10 @@
<!-- Beamline configuration: FTOn is used -->
<detector name="experiments/clas12/ft/ft" factory="TEXT" variation="FTOn"/>
<detector name="experiments/clas12/beamline/cadBeamline/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="FTOn"/>

<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>


<!-- forward carriage -->
Expand Down Expand Up @@ -103,10 +104,9 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, 20" />


<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectUpstreamToTorusPipe, connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />

<!-- torus magnet: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="BoreShield, CenterTube, DownstreamShieldingPlate, DownstreamVacuumJacket, WarmBoreTube, apex, Shield1, Shield2, Shield3, Shield4, Shield5, Shield6, Shield7, shell1a, shell1b, shell2a, shell2b, shell3a, shell3b, shell4a, shell4b, shell5a, shell5b, shell6a, shell6b, 20" />
Expand Down
8 changes: 4 additions & 4 deletions gemc/dev/rgb_fall2019.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -30,9 +30,10 @@
<!-- Beamline configuration: FTOn is used -->
<detector name="experiments/clas12/ft/ft" factory="TEXT" variation="FTOn"/>
<detector name="experiments/clas12/beamline/cadBeamline/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="FTOn"/>

<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>


<!-- forward carriage -->
Expand Down Expand Up @@ -103,10 +104,9 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, 20" />


<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectUpstreamToTorusPipe, connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />

<!-- torus magnet: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="BoreShield, CenterTube, DownstreamShieldingPlate, DownstreamVacuumJacket, WarmBoreTube, apex, Shield1, Shield2, Shield3, Shield4, Shield5, Shield6, Shield7, shell1a, shell1b, shell2a, shell2b, shell3a, shell3b, shell4a, shell4b, shell5a, shell5b, shell6a, shell6b, 20" />
Expand Down
8 changes: 4 additions & 4 deletions gemc/dev/rgb_spring2019.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -30,9 +30,10 @@
<!-- Beamline configuration: FTOn is used -->
<detector name="experiments/clas12/ft/ft" factory="TEXT" variation="FTOn"/>
<detector name="experiments/clas12/beamline/cadBeamline/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="FTOn"/>

<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>


<!-- forward carriage -->
Expand Down Expand Up @@ -103,10 +104,9 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, 20" />


<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectUpstreamToTorusPipe, connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />

<!-- torus magnet: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="BoreShield, CenterTube, DownstreamShieldingPlate, DownstreamVacuumJacket, WarmBoreTube, apex, Shield1, Shield2, Shield3, Shield4, Shield5, Shield6, Shield7, shell1a, shell1b, shell2a, shell2b, shell3a, shell3b, shell4a, shell4b, shell5a, shell5b, shell6a, shell6b, 20" />
Expand Down
10 changes: 5 additions & 5 deletions gemc/dev/rgc_fall2022.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -29,11 +29,11 @@

<!-- Beamline configuration: ELMO is used -->
<detector name="experiments/clas12/beamline/cadBeamlineELMO/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="ELMO"/>
<detector name="connectUpstreamToTorusPipe">
<existence exist="no" />
</detector>

<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>


<!-- forward carriage -->
<detector name="experiments/clas12/fc/forwardCarriage" factory="TEXT" variation="default"/>
Expand Down Expand Up @@ -103,7 +103,7 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, 20" />

<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />
Expand Down
5 changes: 3 additions & 2 deletions gemc/dev/rgc_summer2022.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -30,9 +30,10 @@
<!-- Beamline configuration: FT is used -->
<detector name="experiments/clas12/ft/ft" factory="TEXT" variation="FTOn"/>
<detector name="experiments/clas12/beamline/cadBeamline/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="FTOn"/>

<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>


<!-- forward carriage -->
Expand Down Expand Up @@ -103,7 +104,7 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, 20" />

<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />
Expand Down
8 changes: 4 additions & 4 deletions gemc/dev/rgf_spring2020.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -30,9 +30,10 @@
<!-- Beamline configuration: FTOff is used -->
<detector name="experiments/clas12/ft/ft" factory="TEXT" variation="FTOff"/>
<detector name="experiments/clas12/beamline/cadBeamlineFTOFF/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="FTOff"/>

<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>


<!-- forward carriage -->
Expand Down Expand Up @@ -103,10 +104,9 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, 20" />


<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectUpstreamToTorusPipe, connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />

<!-- torus magnet: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="BoreShield, CenterTube, DownstreamShieldingPlate, DownstreamVacuumJacket, WarmBoreTube, apex, Shield1, Shield2, Shield3, Shield4, Shield5, Shield6, Shield7, shell1a, shell1b, shell2a, shell2b, shell3a, shell3b, shell4a, shell4b, shell5a, shell5b, shell6a, shell6b, 20" />
Expand Down
9 changes: 4 additions & 5 deletions gemc/dev/rgk_fall2018_FTOff.gcard
Original file line number Diff line number Diff line change
Expand Up @@ -30,10 +30,10 @@
<!-- Beamline configuration: FTOff is used -->
<detector name="experiments/clas12/ft/ft" factory="TEXT" variation="FTOff"/>
<detector name="experiments/clas12/beamline/cadBeamlineFTOFF/" factory="CAD"/>
<detector name="experiments/clas12/beamline/vacuumLine/" factory="CAD"/>
<detector name="experiments/clas12/beamline/beamline" factory="TEXT" variation="FTOff"/>


<!-- Downstream beamline configuration -->
<detector name="experiments/clas12/beamline/cad_downstream_beamline/" factory="CAD"/>

<!-- forward carriage -->
<detector name="experiments/clas12/fc/forwardCarriage" factory="TEXT" variation="default"/>
Expand Down Expand Up @@ -103,10 +103,9 @@

<!-- production threshold for passive volumes -->
<!-- beamline shielding: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, DSShieldFrontLead, DSShieldBackLead, DSShieldInnerAss, DSShieldBackAss, DSShieldFrontAss, DSShieldBackCover, DSShieldFrontCover, DSShieldFlangeAttachment, DSShieldFlange, 20" />
<option name="PRODUCTIONCUTFORVOLUMES" value="innerShieldAndFlange, outerFlange, outerMount, nut1, nut2, nut3, nut4, nut5, nut6, nut7, nut8, nut9, taggerInnerShield, main-cone, main-cone, adjuster1, adjuster2, adjuster3, 20" />


<!-- vacuum line: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="connectUpstreamToTorusPipe, connectTorusToDownstreamPipe, downstreamPipeFlange, 20" />

<!-- torus magnet: 2cm-->
<option name="PRODUCTIONCUTFORVOLUMES" value="BoreShield, CenterTube, DownstreamShieldingPlate, DownstreamVacuumJacket, WarmBoreTube, apex, Shield1, Shield2, Shield3, Shield4, Shield5, Shield6, Shield7, shell1a, shell1b, shell2a, shell2b, shell3a, shell3b, shell4a, shell4b, shell5a, shell5b, shell6a, shell6b, 20" />
Expand Down
Loading

0 comments on commit 595f8f0

Please sign in to comment.