VCU-Firmware

Firmware for the vehicle control unit in GRC22-Present. We currently utilize an Espressif ESP32 board as the compute for the VCU. On our roadmap is to move to a in-house designed board.

Setup

  • Install VsCode
  • Install the Platform IO extension through the vs code extensions tab (Ctrl + Shift + x on windows)

Running

Firmware can be run or debugged directly on the ESP32 using the platform IO extension to seamlessly detect and upload software

Resources

Algorithms/Methodoligies used

  • Insulation Monitoring Device (IMD) Readings:

    • The IMD outputs a pwm frequency based on its state
    • IMD outputs pwm duty cycle for resistance
    • This information is decoded and sent out through CAN
  • Pump control frequency and duty cycle calculations:

    • Based on the data sheet, the pump:

      • Requires an input frequency between 50-1000Hz
      • Needs an uninterupted high pulse for 3ms to ensure it is woken up properly
      • Has certain ranges of functionality depending on the duty cycle of the PWM generation, of those features the following are being used:
        • Pump stop -> 0-12% duty cycle
        • Controlled Operation -> 13-85% duty cycle
        • Max speed -> 86-97% duty cycle
    • The ledcSetup() function is used to setup the pwm generator, with the frequency 50Hz with a resolution at 10 bits

    • The Pump GPIO pin is attached to the pwm generator channel using ledcAttachPin()

    • PWM outputs are generated using ledcWrite()

    • To calculate the duty cycle the following formula can be used: $Duty cycle = (2^10 - 1) * desired duty cycle / 100$

      • The bit value is subtracted by 1 since the program starts counting at 0
      • This formula is further changed since the pump control on the Gryphon Racing Shutdown Board contains N channel MOSFET
      • Because of this the Duty cycle value needs to be inverted for the proper output to the pump, the updated formula is as follows: $Duty cycle = (2^10 - 1) - (2^10 - 1) * desired duty cycle / 100$ This formula is used for our max speed and stop cases, this allows us to maintain a consistent speed for the pump
    • For the remaining pump speeds, the following is done:

    • Since the pump cycle function takes an input of the desired pump speed (percentage value), a linear operation is done to ensure that the correct duty cycle value is being selected for the desired speed.

      • Knowing that the original bounds (pump speed) are from 1 - 99% and that they need to be converted to 15 - 85% (15% rather than 13% since the pump will always be on at 15% with the frequency we are using), the following linear mapping is chosen (more information can be found here): $duty cycle = (((X - A)/(B - A)) * (D - C)) + C$ Where A = lower bound of old value (1) B = upper bound of old value (99) C = lower bound of new value (15) D = upper bound of new value (85) X = input value (pump speed in percent) Yielding: $duty cycle = (((pump speed - 1)/(99 - 1)) * (85 - 15)) + 15$