Skip to content

A simple remote control commandline client for pjlink compatible devices

Notifications You must be signed in to change notification settings

Bendr0id/pjlinkControl

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

5 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

pjlinkControl

A simple remote control commandline client for pjlink compatible devices written in Java

usage: [-h] -i <ip> [-p <port>] [-a <authpass>] -c <command>

PjlinkControl 1.0 (http://github.com/Bendr0id/)

 -a,--authpass <authpass>     The Password of the Pjlink device [default: JBMIAProjectorLink]
 -c,--command <command>       The Commant to send to the Pjlink device
 -h,--help                    Prints this help
 -i,--ip <ip>                 The IP of the Pjlink device
 -p,--port <port>             The Port of the Pjlink device [default: 4352]

Available commands:

LAMP ? = Lamp status query
        Result:
                1st digits (1-5) = Lamp cumulative operating time
                2nd digit
                        Values:
                        0 = Lamp off
                        1 = Lamp on

INF1 ? = Manufacturer name query
        Result:
                Manufacturer name

INPT ? = Input selection query
        Result:
                11-19 = RGB 1-9
                21-29 = VIDEO 1-9
                31-39 = DIGITAL 1-9
                41-49 = AUX 1-9
                51-59 = Network 1-9

AVMT = AV MUTE control
        Parameters:
                30 = AV MUTE mode off
                31 = AV MUTE mode on

NAME ? = Device name query
        Result:
                Device name

INF2 ? = Model name query
        Result:
                Model name

INPT = Input selection
        Parameters:
                11-19 = RGB 1-9
                21-29 = VIDEO 1-9
                31-39 = DIGITAL 1-9
                41-49 = AUX 1-9
                51-59 = Network 1-9

POWR = Power supply control
        Parameters:
                0 = Standby
                1 = Power ON

AVMT ? = AV MUTE status query
        Result:
                30 = AV MUTE mode off
                31 = AV MUTE mode on

ERST ? = Error status query
        Result:
                1st byte = Indicates fan errors
                2nd byte = Indicates lamp errors
                3rd byte = Indicates temperature errors
                4th byte = Always 0
                5th byte = Indicates filter errors
                6th byte = Indicates other errors
        Values:
                0 = No error known
                1 = Warning
                2 = Error

INF0 ? = Other information query
        Result:
                Information such as version number is returned

POWR ? = Power supply status query
        Result:
                0 = Standby
                1 = Power ON
                2 = Cool-down in progress
                3 = Warmup

About

A simple remote control commandline client for pjlink compatible devices

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published