Is STM simulation using p-wave tip available? #1

Open
lycheehoo opened this issue Apr 20, 2023 · 22 comments
Open

Is STM simulation using p-wave tip available? #1

lycheehoo opened this issue Apr 20, 2023 · 22 comments

Comments

@lycheehoo
Copy link

Dear editor, I just wonder if these codes can select diferent tip kinds, like p-wave?

@qphensurf
Copy link
Owner

Thank you for your interest in the code. Unfortunately that option is not implemented in the code.

@qphensurf
Copy link
Owner

qphensurf commented Apr 20, 2023 via email

@lycheehoo
Copy link
Author

Thanks for your timely and detailed reply. Yeah, we actually do not know the real state of the tip. But I have read some papers using these p-wave simulated STM images to match their experimental STM images, which can not be perfectly reproduced by s-wave tip. Take one example below Nat. Chem. 15, 53–60 (2023). , the author simulated constant height STM images using s-wave and p-wave tip, respectively. He found images produced by p-wave tip could match the characteristics of the experiments better than s-wave tip. So I just want to have more choice to confirm my experimental data in some special situations : ) Wish you all the best.
image
image

@lycheehoo
Copy link
Author

Hi Lorente, I got another question to ask: When I plot the simulated dI/dV curve using these codes, does the fermi level fit to 0 eV in the output data dIdV_TH_npt_1.dat automatically? Thanks.

@compthesml
Copy link
Collaborator

Hi Lorente, I got another question to ask: When I plot the simulated dI/dV curve using these codes, does the fermi level fit to 0 eV in the output data dIdV_TH_npt_1.dat automatically? Thanks.

Hi,

Yes, the Fermi level is set to 0 eV for all the energies within the code.

Best,

Roberto

@lycheehoo
Copy link
Author

Thanks Roberto, I have a technical question for you: when I am going to get the simulated LDOS, I need to input the corresponding tip-sample bias, so what is the criteria for the bias input? It is based on whether our STS experimental bias or calculated PDOS bias?

@qphensurf
Copy link
Owner

Usually the calculated bias do not correspond to the experimental one due to the shortcomings of DFT. So you have to find the calculated bias that corresponds to the experimental one. For example, if you have a molecule on the surface and you are probing the HOMO on the surface in the experiment, you should simulate the LDOS at the bias at which the HOMO is in the calculation. Since it doesn´t take much time to calculate an extra point in the same run of STMpw, we usually compute several voltages corresponding to the different peaks in the theoretical PDOS. Then we compare the maps with the experimental results.

Best,

Roberto

@lycheehoo
Copy link
Author

Usually the calculated bias do not correspond to the experimental one due to the shortcomings of DFT. So you have to find the calculated bias that corresponds to the experimental one. For example, if you have a molecule on the surface and you are probing the HOMO on the surface in the experiment, you should simulate the LDOS at the bias at which the HOMO is in the calculation. Since it doesn´t take much time to calculate an extra point in the same run of STMpw, we usually compute several voltages corresponding to the different peaks in the theoretical PDOS. Then we compare the maps with the experimental results.

Best,

Roberto

OK, I am clear now, thanks.

@lycheehoo
Copy link
Author

Usually the calculated bias do not correspond to the experimental one due to the shortcomings of DFT. So you have to find the calculated bias that corresponds to the experimental one. For example, if you have a molecule on the surface and you are probing the HOMO on the surface in the experiment, you should simulate the LDOS at the bias at which the HOMO is in the calculation. Since it doesn´t take much time to calculate an extra point in the same run of STMpw, we usually compute several voltages corresponding to the different peaks in the theoretical PDOS. Then we compare the maps with the experimental results.
Best,
Roberto

OK, I am clear now, thanks.

If I want to get the simulated LDOS of specific tip-simple bias, all I need to do is just change the "cube output" to "T"? And the output TH_V_bias.cube file is the LDOS information and the .TH_V_bias.siesta is the constant height/current STM image?

@qphensurf
Copy link
Owner

.dat, .cube, and .siesta files contain the same information. For example, TH_V_bias.dat, TH_V_bias.cube and TH_V_bias.siesta contain the STM topography in the Tersoff-Hamann approximation. .dat files can be plotted with the utilities in the Utils directory; .siesta files can be plotted with WsXM; and .cube files can be plotted with different programs.

LDOS is proportional to dI/dV, so if you want to plot a LDOS map, this is called dIdV in the output files. For example, dIdV_TH_V_bias.dat. To plot it just use the utilities in the Utils directory, in particular the Cond_gnu.f90 program.

@lycheehoo
Copy link
Author

Very convenient tools, so the following output dIdV_TH_V_bias.cube files are the genuine simulated maps data? And I can plot them in WsXM.
image

@lycheehoo
Copy link
Author

Dear developer, I got questions on plotting dIdV_TH_bias.dat using Cond_gnu.fortran program. How to set the parameters "height" and "current"? What is the true meaning of them? And when I set the "height" of "2", there is all zero in the 3rd line of the output "Conductance.gnu".

@qphensurf
Copy link
Owner

"height" is the height over the surface (Zsurf in input.STMpw) in angstroms. It has to be higher than z_s, so a height of 2 is too small. Just increase it. "Current" is the current in arbitrary units. Typical values can be from 1e-7 to 1e-10, but they depend on your system.

@lycheehoo
Copy link
Author

Thanks, it runs successfully. And could you please tell me how to plot it by gnuplot? I just type "set pm3d" "splot Conductance.gnu", but the output image is awful.

@qphensurf
Copy link
Owner

Take a look at the cond_V_cc.sh and cond_V_ch.sh scripts in the Utils directory. They produce nice png images from gnuplot.

@lycheehoo
Copy link
Author

Hello, I want to use this software to simulate the experimental didv maps using gas phase molecule. So are these codes available for didv simulation on just isolated molecule (no substrate)? Thanks!

@lorente
Copy link
Collaborator

lorente commented Nov 12, 2023 via email

@lycheehoo
Copy link
Author

Dear Nicolás, I try to calculate the simulated di/dv maps (LDOS) of specific orbitals, like HOMO, LUMO... So I want to know how to get the corresponding LDOS of specific state? For single molecules, I try to use the energy in EIGENVAL file, and I set the simulated bias to corresponding state energy, but the outcomes are strange.
I'm looking forward to your reply, thanks! :)

@lorente
Copy link
Collaborator

lorente commented Mar 30, 2024 via email

@lycheehoo
Copy link
Author

Thanks for your detailed response! Yes, I want to get a single molecular orbtal dI/dV map, so I calculate the molecule without substrate. And I look at the electron occupation in the EIGENVAL file to know the HOMO and other orbitals' energy. My input and output files are shown below.
For example, the LUMO's energy is -1.820794 eV (from EIGENVAL), and the Fermi energy determined by VASP is -2.7686 eV (from OUTCAR), so if I want the simulated maps of LUMO, I need to set the bias in input.STMpw as 0.948 V. Is this right?
inputfile.zip

@lorente
Copy link
Collaborator

lorente commented Apr 2, 2024 via email

@lycheehoo
Copy link
Author

OK, thank you very much :)