EMH meter is only responding with ACK on read. #8
Comments
Only the R5 command is mentioned in the EMH manual. Maybe need to contact tech support att EMH. |
Closed
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
When trying to solve some user issues: #4 I found (after some other fixes #7 ) that my test EMH meter is responding with only an ACK on a read command (R1). As I read the standard read commands should be answered directly with the data.
If I wait i get a BREAK message from the meter so it seems that the meter expects me to send more data in the read-command. But it is not a partial blocks command (R3/R4) so it seems wrong.
I have check with the manufacturers documentation.
The text was updated successfully, but these errors were encountered: