Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathmain.go
191 lines (163 loc) · 5.58 KB
/
main.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
package main
import (
"context"
"fmt"
"net/http"
"os"
"os/exec"
"os/signal"
"regexp"
"strconv"
"syscall"
"time"
"github.com/prometheus/client_golang/prometheus"
"github.com/prometheus/client_golang/prometheus/promhttp"
"github.com/rs/zerolog"
"github.com/rs/zerolog/log"
"github.com/spf13/viper"
)
var (
instantaneousPowerGauge = prometheus.NewGauge(prometheus.GaugeOpts{
Name: "ipmi_instantaneous_power_watts",
Help: "Instantaneous power reading in watts",
})
minimumPowerGauge = prometheus.NewGauge(prometheus.GaugeOpts{
Name: "ipmi_minimum_power_watts",
Help: "Minimum power reading in watts during the sampling period",
})
maximumPowerGauge = prometheus.NewGauge(prometheus.GaugeOpts{
Name: "ipmi_maximum_power_watts",
Help: "Maximum power reading in watts during the sampling period",
})
averagePowerGauge = prometheus.NewGauge(prometheus.GaugeOpts{
Name: "ipmi_average_power_watts",
Help: "Average power reading in watts over the sample period",
})
)
func init() {
// Register the Prometheus gauges
prometheus.MustRegister(instantaneousPowerGauge)
prometheus.MustRegister(minimumPowerGauge)
prometheus.MustRegister(maximumPowerGauge)
prometheus.MustRegister(averagePowerGauge)
// Initialize Viper
viper.SetConfigName("ipmi_power_exporter")
viper.SetConfigType("yaml")
viper.AddConfigPath("/etc/")
viper.AddConfigPath(".")
// Read the configuration file
if err := viper.ReadInConfig(); err != nil {
log.Fatal().Err(err).Msg("Error reading config file")
}
// Set up logging
zerolog.TimeFieldFormat = zerolog.TimeFormatUnix
logLevel := viper.GetString("log.level")
logFormat := viper.GetString("log.format")
switch logFormat {
case "json":
log.Logger = log.Output(os.Stderr)
case "pretty":
log.Logger = log.Output(zerolog.ConsoleWriter{Out: os.Stderr})
default:
log.Fatal().Msg("Invalid log format specified")
}
switch logLevel {
case "debug":
zerolog.SetGlobalLevel(zerolog.DebugLevel)
case "info":
zerolog.SetGlobalLevel(zerolog.InfoLevel)
case "warn":
zerolog.SetGlobalLevel(zerolog.WarnLevel)
case "error":
zerolog.SetGlobalLevel(zerolog.ErrorLevel)
default:
log.Fatal().Msg("Invalid log level specified")
}
}
func collectPowerMetrics(ctx context.Context, host string, user string, pass string) {
// Regular expressions to match the power readings
instantaneousRegex := regexp.MustCompile(`Instantaneous power reading:\s+(\d+) Watts`)
minimumRegex := regexp.MustCompile(`Minimum during sampling period:\s+(\d+) Watts`)
maximumRegex := regexp.MustCompile(`Maximum during sampling period:\s+(\d+) Watts`)
averageRegex := regexp.MustCompile(`Average power reading over sample period:\s+(\d+) Watts`)
// Extract the power readings
extractValue := func(regex *regexp.Regexp, metric prometheus.Gauge, outputStr string) float64 {
match := regex.FindStringSubmatch(outputStr)
if len(match) == 2 {
value, err := strconv.ParseFloat(match[1], 64)
if err != nil {
log.Error().Err(err).Msg("Error parsing power reading")
return -1
}
metric.Set(value)
return value
}
return -1
}
// Building command line params
params := []string{}
if host != "" {
params = []string{"-I", "lanplus", "-H", host, "-U", user, "-P", pass}
}
params = append(params, "dcmi", "power", "reading")
log.Info().Msg("Collecting data")
log.Debug().Interface("params", params).Msg("calling ipmitools with params")
// Execute the ipmitool command with user and password
cmd := exec.CommandContext(ctx, "ipmitool", params...)
output, err := cmd.CombinedOutput()
if err != nil {
log.Error().Err(err).Msg("Error executing ipmitool")
return
}
// Convert the output to a string
outputStr := string(output)
// Extract and set the power readings
cval := extractValue(instantaneousRegex, instantaneousPowerGauge, outputStr)
minval := extractValue(minimumRegex, minimumPowerGauge, outputStr)
maxval := extractValue(maximumRegex, maximumPowerGauge, outputStr)
avgval := extractValue(averageRegex, averagePowerGauge, outputStr)
log.Debug().
Str("current", fmt.Sprintf("current: %0.2f Watt", cval)).
Str("min", fmt.Sprintf("min: %0.2f Watt", minval)).
Str("max", fmt.Sprintf("max: %0.2f Watt", maxval)).
Str("avg", fmt.Sprintf("avg: %0.2f Watt", avgval)).
Msg("Collected power metrics")
}
func main() {
// Get the IPMI configuration
host := viper.GetString("ipmi.host")
user := viper.GetString("ipmi.user")
pass := viper.GetString("ipmi.pass")
// Get the collect interval and listen port from the configuration
collectInterval := viper.GetDuration("collect.interval")
listenPort := viper.GetInt("server.port")
listenAddress := viper.GetString("server.address")
// Start polling in the background
go func() {
ticker := time.NewTicker(collectInterval)
defer ticker.Stop()
// Create a context that can be cancelled
ctx, cancel := context.WithCancel(context.Background())
defer cancel()
// Set up a signal handler to cancel the context
sigCh := make(chan os.Signal, 1)
signal.Notify(sigCh, syscall.SIGINT, syscall.SIGTERM)
// Start a goroutine to periodically collect metrics
for {
select {
case <-ticker.C:
collectPowerMetrics(ctx, host, user, pass)
case <-ctx.Done():
os.Exit(-1)
case sig := <-sigCh:
log.Info().Str("signal", sig.String()).Msg("Received signal, shutting down")
os.Exit(0)
}
}
}()
// Expose the registered metrics via HTTP
addr := fmt.Sprintf("%s:%d", listenAddress, listenPort)
http.Handle("/metrics", promhttp.Handler())
log.Info().Msgf("starting power consume exporter daemon on %s", addr)
log.Fatal().Err(http.ListenAndServe(addr, nil)).Msg("power consume exporter daemon stopped")
}