Good evening, I have a problem with my FreeDS.
I've been using it for 1 year and until last month without any problems with the Shelly EM data source.
Now my data source is a Huawei inverter with battery Luna2000 and the configuration is:
Modbus Port :502
Meter Id:1
Error wait time (ms):20000
Data acquisition time (ms):1500
and it is constantly in error: "Measurement data reception error".
It stop running a lot of times.
Thanks.
The text was updated successfully, but these errors were encountered:
Si estas usando huawei debes fijar la adquisición de datos a una velocidad de 150 o 200ms, ya que la lectura se realiza en varios registros consecutivos en lugar de obtenerlos todos en cada petición como se hace con Shelly.
Good evening, I have a problem with my FreeDS.
I've been using it for 1 year and until last month without any problems with the Shelly EM data source.
Now my data source is a Huawei inverter with battery Luna2000 and the configuration is:
Modbus Port :502
Meter Id:1
Error wait time (ms):20000
Data acquisition time (ms):1500
and it is constantly in error: "Measurement data reception error".
It stop running a lot of times.
Thanks.