Skip to content

Sending data package only reboots remote device into ShortFast #74

@KlfJoat

Description

@KlfJoat

Hi,

When trying to send a data package between 2 EUDs, the remote Meshtastic device reboots into ShortFast, but the local device does not.

EUD "A"

  • Amazon Fire HD 8 (12th Generation)
    • Wi-Fi: OFF
    • Nothing physically plugged in
    • Nothing connected via Bluetooth (besides the Meshtastic device)
  • ATAK v5.5.1.3
    • No TakServer configured or available.
  • ATAK Meshtastic plugin v1.1.18 - 5.5.0
    • Only send PLI and Chat messages over Meshtastic: OFF
    • Allow SWITCH command: ON
  • Meshtastic for F-Droid v2.7.3 (downloaded from GitHub, installed via APK)
  • Seeed Wio Tracker L1 Pro
    • Meshtastic v2.7.11
    • LongFast
    • Channel 0 is private
    • Slot: 20
    • Role: TAK

EUD "B"

  • Google Pixel 7 Pro
    • Nothing physically plugged in
    • Nothing connected via Bluetooth (besides the Meshtastic device)
  • ATAK v5.5.1.3
    • No TakServer configured or available.
  • ATAK Meshtastic plugin v1.1.18 - 5.5.0
    • Only send PLI and Chat messages over Meshtastic: OFF
    • Allow SWITCH command: ON
  • Meshtastic for F-Droid v2.7.3 (downloaded from GitHub, installed via APK)
  • Lilygo T-Echo
    • Meshtastic 2.7.11
    • LongFast
    • Channel 0 is private
    • Slot: 20
    • Role: TAK

(Each setting was verified)

Regular messaging between devices works.

If I send from A to B, then B's Meshtastic device (Lilygo T-Echo) reboots into ShortTurbo. The Seeed Wio Tracker L1 Pro does nothing and remains in LongFast.

If I send from B to A, then A's Meshtastic device (Seeed Wio Tracker L1 Pro) reboots into ShortTurbo. The Lilygo T-Echo does nothing and remains in LongFast.

This also happened with 2.6.30 firmware, 2.6 apps, and v1.1.16 ATAK plugin, though then it rebooted into ShortFast, not ShortTurbo.

With 2.6 and 1.1.16, if I manually set both devices into ShortFast, they would send.

Now, with 2.7 and 1.1.18, if I manually set them to ShortFast, the remote device reboots into ShortTurbo. If I manually set both to ShortTurbo, when I hit send in ATAK, an ATAK window pops up for a quarter second too fast to read, then goes away, I get no error message, and I see no "Transfer" notification from ATAK.