Skip to content

Commit 55074ab

Browse files
Fixed link in readme
1 parent 920ea1b commit 55074ab

File tree

1 file changed

+2
-2
lines changed

1 file changed

+2
-2
lines changed

documentation/extra_doc/0_common.md

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -85,7 +85,7 @@ Figure 2: <i>Side view of complex mDOM PMT model. Image from <a href="https://ze
8585

8686
## Optical Modules and Harness Construction
8787

88-
For most optical modules, complex geometries like holding structures and harnesses are constructed from CAD files (`.obj` - see [CAD geometries](2_technicalities.md#cad-geometries)). Using CAD files might increase the geometry construction time. However, once the geometry is initialized, the rest of the simulation proceeds as usual. Therefore, users are advised to structure their simulations to minimize repeated geometry construction. The mDOM is however fully constructed natively in Geant4. For details on the harness implementation, refer to [this Bachelor thesis](https://www.uni-muenster.de/imperia/md/content/physik_kp/agkappes/abschlussarbeiten/bachelorarbeiten/ba_moritz_schlechtriem.pdf).
88+
For most optical modules, complex geometries like holding structures and harnesses are constructed from CAD files (`.obj` - see [CAD geometries](md_extra__doc_22__technicalities.html#autotoc_md43)). Using CAD files might increase the geometry construction time. However, once the geometry is initialized, the rest of the simulation proceeds as usual. Therefore, users are advised to structure their simulations to minimize repeated geometry construction. The mDOM is however fully constructed natively in Geant4. For details on the harness implementation, refer to [this Bachelor thesis](https://www.uni-muenster.de/imperia/md/content/physik_kp/agkappes/abschlussarbeiten/bachelorarbeiten/ba_moritz_schlechtriem.pdf).
8989

9090

9191
The following geometries cannot be visualized:
@@ -162,7 +162,7 @@ Figure 3: <i>PMT response compared to measurement for different light sources. I
162162
</div>
163163
</div>
164164

165-
If you use the complex PMT model, you will obtain detection probability weights, which are the product of quantum efficiency (QE)—which varies with photon wavelength—and collection efficiency weight (which depends on absorption position). These weights are calibrated to match measurements. For more technical details, see the section [Matching PMT Efficiency to Measurements](md_extra__doc_22__technicalities.html#autotoc_md35).
165+
If you use the complex PMT model, you will obtain detection probability weights, which are the product of quantum efficiency (QE)—which varies with photon wavelength—and collection efficiency weight (which depends on absorption position). These weights are calibrated to match measurements. For more technical details, see the section [Matching PMT Efficiency to Measurements](md_extra__doc_22__technicalities.html#autotoc_md37).
166166

167167
In contrast, with the simple PMT model, the detection probability weight is solely the QE. Since the measured QE is reduced due to absorption in the PMT glass, the simulated tube glass will have no defined absorption length.
168168

0 commit comments

Comments
 (0)