RX data loss on on pluto and other SDRs #1167

Closed
vvsvvsvvs opened this issue May 12, 2024 · 1 comment
Closed

RX data loss on on pluto and other SDRs #1167

vvsvvsvvs opened this issue May 12, 2024 · 1 comment

Comments

@vvsvvsvvs
Copy link

vvsvvsvvs commented May 12, 2024

When RX is on, the number of buffers (default 4) NB_BLOCKS in iiod is too small, so there are data duplicates when operating on high rates (>= 3Msmpl/sec). So, increasing the value (16+) solves the problem.
Also reported on

Also, the 16+ buffers reduces the temperature of AD (hm...ok).
Tested on Pluto+ SDR.

@tfcollins
Copy link
Contributor

Not really sure what the question(s) are here. Overflows are really dependent on a few settings and not just number of buffers, as well as the behavior of your program.

Pluto+ is not an ADI product so we would point you to the maintainer.