Sub-argument 'duration' for "TL" measurements #6

Open
tzerk opened this issue Jul 26, 2016 · 1 comment
Open

Sub-argument 'duration' for "TL" measurements #6

tzerk opened this issue Jul 26, 2016 · 1 comment

Comments

@tzerk
Copy link
Member

tzerk commented Jul 26, 2016

Don't know whether this is feasible or within the scope of the included models, but it would be nice to have the simulated TL measurements have an additional argument duration stating the duration (in seconds) the final temperature should be held for.

This would enable to replace PH and CH with TL measurements so we can have actual data on the TL measurements that we can trace throughout a SAR sequence (as PH and CH produce no RLum.Data.Curve) object.

@JohannesFriedrich
Copy link
Collaborator

That should be possible. I have to check in 'translate_sequence' if this sub-argument is set and then modify.