You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
When circuit is in OPEN state, and after sleepWindow time over, the first request execute and if it give 400 or any HystrixBadRequestException, the state remain the same i.e OPEN. and it trigger the sleepWindow again. which cause agin to be in fallback and this add on the sleepWindow again and again.
Is this behaviour correct ? Since 400 means the client server is up , and it serve the calls, while it give 400, didn’t we close the circuit.
The text was updated successfully, but these errors were encountered:
When circuit is in OPEN state, and after sleepWindow time over, the first request execute and if it give 400 or any HystrixBadRequestException, the state remain the same i.e OPEN. and it trigger the sleepWindow again. which cause agin to be in fallback and this add on the sleepWindow again and again.
Is this behaviour correct ? Since 400 means the client server is up , and it serve the calls, while it give 400, didn’t we close the circuit.
The text was updated successfully, but these errors were encountered: